Jump to content

LabVIEW 2020: Difference between revisions

From LabVIEW Wiki
Add information about LV 2020 SP1
Added Transport Layer Security Functions as new feature
 
(4 intermediate revisions by 2 users not shown)
Line 4: Line 4:
|logo=File:LV2020.png
|logo=File:LV2020.png
|release=May 2020
|release=May 2020
|release_sp1=January 2021
|release_sp1=January 2021 (SP1)
|change_0=Interfaces
|change_0=Interfaces
|change_1=Partially broken wires
|change_1=Partially broken wires
|change_2=Publish web services to NI Web Server
|change_2=Publish web services to NI Web Server
|change_3=Repairing packages
|change_3=Repairing packages
|change_4=Clear variant data types}}
|change_4=Clear variant data types
|change_5=Transport Layer Security Functions}}
 
==New features in LabVIEW 2020==
{{ambox|text=This is a subset of new features in LabVIEW 2020 that were mentioned on [https://twitter.com/labview Twitter] and [https://www.facebook.com/labview/ Facebook]. See the Upgrade Notes for a complete list of changes.}}
* Interfaces - Expanded object-oriented programming to introduce interfaces as a companion feature to classes.
* Clear Variant Data right-click menu option<ref name="fb-clear-variant-data"/> - Clears data from Variant controls and indicators.
* Enum to Array of Enums function<ref name="fb-enum-to-array-of-enums"/> - Creates an array with all possible Enum values.
* Create NI GUID function<ref name="fb-create-ni-guid"/> - Adds a native GUID function to LabVIEW.
* Remove <code> (no error)</code> from Error Control (hidden INI key)<ref name="fb-remove-no-error-from-error-control"/> - Set <code>NI.LV.RemoveNoError=TRUE</code> to remove the <code> (no error)</code> suffix from Error Controls.
* Build Path Relative Path Input<ref name="fb-build-path-relative-path-input"/> - The default type for the second input of the Build Path function was changed to relative Path instead of String.
* Break Bad Wire Branches Only<ref name="fb-break-bad-wires-only"/> - Wires only break for broken branches instead of all branches.
* Class Dialog Improvements<ref name="fb-class-dialog-improvements"/> - The dialog for creating new classes was changed to provide more features.
* Double Click Array To Cluster<ref name="fb-double-click-array-to-cluster"/> - The property dialog for the Array To Cluster function can now be opened by a double-click.
* Set Text Icon for Project Libraries<ref name="fb-edit-icons"/> - The Project Library configuration dialog has a new ''Set Text Icon...'' button, which provides a way to quickly set the text, text color and background color for the library icon.
* Range Limits for Type<ref name="fb-range-limits-for-type-vi"/> - Returns the maximum and minimum values for a given data type.
* Generate Checksum Values<ref name="fb-generate-checksum-values"/> - Adds native functions to calculate SHA-2 and SHA-3 checksums to LabVIEW.
* Hide Event Data Node and Iteration Terminal<ref name="fb-hide-event-data-node-and-iteration-terminal"/> - It is now possible to hide Event Data Nodes in Event Structures and Iteration Terminals on For- and While loops.
* Multi-Error Support<ref name="fb-multi-error-support"/> - Collect multiple error values on a single error wire (adds a new subpalette for handling multiple errors).
* Hide Last Item for Rings when running<ref name="fb-hide-last-item-for-rings"/> - Adds an option to hide the last item from a ring control.
* Transport Layer Security Functions (TLS) for TCP/IP communication
 
==Application icon design==
The application icon was changed for LabVIEW 2020 SP1:
 
[[File:LV2020SP1.png]]


==External links==
==External links==
Line 21: Line 46:
* [https://youtu.be/rXLxo9zuBSc What’s new in LabVIEW 2020] by Tom’s LabVIEW Adventure
* [https://youtu.be/rXLxo9zuBSc What’s new in LabVIEW 2020] by Tom’s LabVIEW Adventure


==Application icon design==
==References==
The application icon was changed for LabVIEW 2020 SP1:
<references>
 
<ref name="fb-clear-variant-data">[https://www.facebook.com/labview/videos/313204460045993 Clear Variant Data] by Darren Nattinger</ref>
[[File:LV2020SP1.png]]
<ref name="fb-enum-to-array-of-enums">[https://www.facebook.com/labview/videos/283647629401421 Enum to Array of Enums] by Darren Nattinger</ref>
<ref name="fb-create-ni-guid">[https://www.facebook.com/labview/videos/570111097012827 Create NI GUID.vi] by Darren Nattinger</ref>
<ref name="fb-remove-no-error-from-error-control">[https://www.facebook.com/labview/videos/615411719411123 Remove (no error) From Error Control] by Darren Nattinger</ref>
<ref name="fb-build-path-relative-path-input">[https://www.facebook.com/labview/videos/299469061159932 Build Path Relative Path Input] by Darren Nattinger</ref>
<ref name="fb-break-bad-wires-only">[https://www.facebook.com/labview/videos/672708713385685 Break Bad Wires Only] by Darren Nattinger</ref>
<ref name="fb-class-dialog-improvements">[https://www.facebook.com/labview/videos/3102767176494288 Class Dialogue Improvements] by Darren Nattinger</ref>
<ref name="fb-double-click-array-to-cluster">[https://www.facebook.com/labview/videos/349473259602855 Double Click Array To Cluster] by Darren Nattinger</ref>
<ref name="fb-edit-icons">[https://www.facebook.com/labview/videos/350338116077871 Edit Icons] by Darren Nattinger</ref>
<ref name="fb-range-limits-for-type-vi">[https://www.facebook.com/labview/videos/690573941892844 Range Limits for Type VI] by Darren Nattinger</ref>
<ref name="fb-generate-checksum-values">[https://www.facebook.com/labview/videos/1254380881613189 Generate Checksum Values] by Darren Nattinger</ref>
<ref name="fb-hide-event-data-node-and-iteration-terminal">[https://www.facebook.com/labview/videos/372715580702001 Hide Event Data Node and Iteration Terminal] by Darren Nattinger</ref>
<ref name="fb-multi-error-support">[https://www.facebook.com/labview/videos/191762282418740 Multi-Error Support] by Darren Nattinger</ref>
<ref name="fb-hide-last-item-for-rings">[https://www.facebook.com/labview/videos/842160236599572 Hide Last Item for Rings] by Darren Nattinger</ref>
</references>


{{stub}}
{{stub}}


[[Category:LabVIEW Versions]]
[[Category:LabVIEW Versions]]

Latest revision as of 19:34, 30 March 2026

LabVIEW 2020
Release Date(s)
  • May 2020
  • January 2021 (SP1)


Key Features and Changes
  • Interfaces
  • Partially broken wires
  • Publish web services to NI Web Server
  • Repairing packages
  • Clear variant data types
  • Transport Layer Security Functions




New features in LabVIEW 2020

  • Interfaces - Expanded object-oriented programming to introduce interfaces as a companion feature to classes.
  • Clear Variant Data right-click menu option[1] - Clears data from Variant controls and indicators.
  • Enum to Array of Enums function[2] - Creates an array with all possible Enum values.
  • Create NI GUID function[3] - Adds a native GUID function to LabVIEW.
  • Remove (no error) from Error Control (hidden INI key)[4] - Set NI.LV.RemoveNoError=TRUE to remove the (no error) suffix from Error Controls.
  • Build Path Relative Path Input[5] - The default type for the second input of the Build Path function was changed to relative Path instead of String.
  • Break Bad Wire Branches Only[6] - Wires only break for broken branches instead of all branches.
  • Class Dialog Improvements[7] - The dialog for creating new classes was changed to provide more features.
  • Double Click Array To Cluster[8] - The property dialog for the Array To Cluster function can now be opened by a double-click.
  • Set Text Icon for Project Libraries[9] - The Project Library configuration dialog has a new Set Text Icon... button, which provides a way to quickly set the text, text color and background color for the library icon.
  • Range Limits for Type[10] - Returns the maximum and minimum values for a given data type.
  • Generate Checksum Values[11] - Adds native functions to calculate SHA-2 and SHA-3 checksums to LabVIEW.
  • Hide Event Data Node and Iteration Terminal[12] - It is now possible to hide Event Data Nodes in Event Structures and Iteration Terminals on For- and While loops.
  • Multi-Error Support[13] - Collect multiple error values on a single error wire (adds a new subpalette for handling multiple errors).
  • Hide Last Item for Rings when running[14] - Adds an option to hide the last item from a ring control.
  • Transport Layer Security Functions (TLS) for TCP/IP communication

Application icon design

The application icon was changed for LabVIEW 2020 SP1:

External links

References

  1. ↑ Clear Variant Data by Darren Nattinger
  2. ↑ Enum to Array of Enums by Darren Nattinger
  3. ↑ Create NI GUID.vi by Darren Nattinger
  4. ↑ Remove (no error) From Error Control by Darren Nattinger
  5. ↑ Build Path Relative Path Input by Darren Nattinger
  6. ↑ Break Bad Wires Only by Darren Nattinger
  7. ↑ Class Dialogue Improvements by Darren Nattinger
  8. ↑ Double Click Array To Cluster by Darren Nattinger
  9. ↑ Edit Icons by Darren Nattinger
  10. ↑ Range Limits for Type VI by Darren Nattinger
  11. ↑ Generate Checksum Values by Darren Nattinger
  12. ↑ Hide Event Data Node and Iteration Terminal by Darren Nattinger
  13. ↑ Multi-Error Support by Darren Nattinger
  14. ↑ Hide Last Item for Rings by Darren Nattinger