LabVIEW configuration file/Block Diagram
From LabVIEW Wiki
This is a list of LabVIEW ini File settings relating to Block Diagram behaviour.
allowDragDropFromFileDlg
Example: allowDragDropFromFileDlg=TRUE
Description: Enables drag and drop functionality from the file dialog to the block diagram of a vi
Datatype:
Boolean
Permitted Values: TRUE or FALSE
Default Value: FALSE
LabVIEW Versions:
8.5,
OS's Supported:
Notes: This functionality existed in LV 5.0 -> LV 7.1, was removed in LV 8.x, and added back in as an ini setting in 8.5
autoWireMax
Example: autoWireMax=24
Description: Maximum distance between nodes for autowiring to be active
Datatype:
Integer
Permitted Values: 1 to 232
Default Value: 16
LabVIEW Versions:
6.x,
7.x,
8.x,
OS's Supported:
Notes: This setting is only effective if enableAutoWire is set to TRUE
autoWireMin
Example: autoWireMin=8
Description: Minimum distance between nodes for autowiring to be active
Datatype:
Integer
Permitted Values: 1 to 232
Default Value: 4
LabVIEW Versions:
6.x,
7.x,
8.x,
OS's Supported:
Notes: This setting is only effective if enableAutoWire is set to TRUE
copyDeleteFPDCOFromFPTerm
Example: copyDeleteFPDCOFromFPTerm=TRUE
Description: Delete front panel terminals from diagram
Datatype:
Boolean
Permitted Values: TRUE or FALSE
Default Value: FALSE
LabVIEW Versions:
4.x,
5.x,
6.x,
7.x,
8.x
OS's Supported:
Notes: None
enableAutoWire
Example: enableAutoWire=FALSE
Description: Enable Auto Wiring
Datatype:
Boolean
Permitted Values: TRUE or FALSE
Default Value: TRUE
LabVIEW Versions:
6.x,
7.x,
8.x,
OS's Supported:
Notes: None
FancyFPTerms
Example: FancyFPTerms=FALSE
Description: Place front panel terminals as icons
Datatype:
Boolean
Permitted Values: TRUE or FALSE
Default Value: (Depends on LV Version)
LabVIEW Versions:
7.x,
8.x,
OS's Supported:
Notes: http://forums.lavag.org/FancyFPTerms-in-LabVIEWini-t725.html
funkyErrClustWire
Example: funkyErrClustWire=FALSE
Description: Change Error Cluster wires color from the standard cluster pink to a more distinctive brown/green color
Datatype:
Boolean
Permitted Values: TRUE or FALSE
Default Value: LabVIEW 5.1, 6.x, 7.x: FALSE, LabVIEW 8.x: TRUE
LabVIEW Versions:
5.x,
6.x,
7.x,
8.x,
OS's Supported:
Notes: None
inlineSubVIEnabled
Example: inlineSubVIEnabled=FALSE
Description: Allows the context menu item "Inline SubVI" on any SubVI which inserts the code directly into the block diagram containing the SubVI.
Datatype:
Boolean
Permitted Values: TRUE or FALSE
Default Value: FALSE
LabVIEW Versions:
6.x,
7.x,
8.x,
OS's Supported:
Notes: None
maxUndoSteps
Example: maxUndoSteps=50
Description: Maximum undo steps per VI
Datatype:
Integer
Permitted Values: 1 to 99
Default Value: 8
LabVIEW Versions:
5.x,
6.x,
7.x,
8.x,
OS's Supported:
Notes: None
showSubVIName
Example: showSubVIName=TRUE
Description: Show subVI names when dropped
Datatype:
Boolean
Permitted Values: TRUE or FALSE
Default Value: FALSE
LabVIEW Versions:
4.x,
5.x,
6.x,
7.x,
8.x,
OS's Supported:
Notes: None
showTipStringsOnTerms
Example: showTipStringsOnTerms=FALSE
Description: Show tip-strips over terminals
Datatype:
Boolean
Permitted Values: TRUE or FALSE
Default Value: TRUE
LabVIEW Versions:
4.x,
5.x,
6.x,
7.x,
8.x,
OS's Supported:
Notes: None
showWireDots
Example: showWireDots=TRUE
Description: Show dots at wire junctions
Datatype:
Boolean
Permitted Values: TRUE or FALSE
Default Value: FALSE
LabVIEW Versions:
7.x,
8.x,
OS's Supported:
Notes: None
showWireGuides
Example: showWireGuides=FALSE
Description: Show dashed line while wiring
Datatype:
Boolean
Permitted Values: TRUE or FALSE
Default Value: TRUE
LabVIEW Versions:
4.x,
5.x,
6.x,
7.x,
8.x,
OS's Supported:
Notes: None
structuresFadeToDiagramBeneath
Example: structuresFadeToDiagramBeneath=FALSE
Description: Makes the diagram of structures semi-transparent so that you can see objects behind them.
Datatype:
Boolean
Permitted Values: TRUE or FALSE
Default Value: TRUE
LabVIEW Versions:
6.x,
7.x,
8.x,
OS's Supported:
Notes: Enabling this setting will slow down the development environment on large Block Diagrams
transparentBDLabels
Example: transparentBDLabels=TRUE
Description: Use transparent name labels
Datatype:
Boolean
Permitted Values: TRUE or FALSE
Default Value: FALSE
LabVIEW Versions:
5.x,
6.x,
7.x,
8.x,
OS's Supported:
Notes: None
UseNumbersForNewVIIcons
Example: UseNumbersForNewVIIcons=FALSE
Description: Tells LabVIEW whether to automatically include a number (1-9) in the lower-right corner of each new VI's icon.
Datatype:
Boolean
Permitted Values: TRUE or FALSE
Default Value: TRUE
LabVIEW Versions:
8.6,
OS's Supported:
Notes: This key replaces UseNumbersForNewVIIconsInLibs from LabVIEW 8.5.
UseNumbersForNewVIIconsInLibs
Example: UseNumbersForNewVIIconsInLibs=FALSE
Description: Tells LabVIEW whether to automatically include a number (1-9) in the lower-right corner of each new VI's icon for VIs created inside libraries (.lvlib, .lvclass, .xctl, .lvsc, etc).
Datatype:
Boolean
Permitted Values: TRUE or FALSE
Default Value: TRUE
LabVIEW Versions:
8.5,
OS's Supported:
Notes: This key was replaced by UseNumbersForNewVIIcons in LabVIEW 8.6.
viCaptionTipStrings
Example: viCaptionTipStrings=FALSE
Description: Use control captions for subVI tip-strips
Datatype:
Boolean
Permitted Values: TRUE or FALSE
Default Value: TRUE
LabVIEW Versions:
5.x,
6.x,
7.x,
8.x,
OS's Supported:
Notes: None
SourceOnlyEnvironment
Example: SourceOnlyEnvironment=True
Description: The option "Separate Compiled Code from Source" is turned on by default
Datatype:
Boolean
Permitted Values: TRUE or FALSE
Default Value: FALSE
LabVIEW Versions:
10,